Installation
ArGeTon bricks can be fixed with one of two aluminium systems: a substructure of vertical or horizontal aluminium profiles.
ArGeTon installation instructions – download
This substructure consists of a mounting bracket (console) and a vertical “T” profile (120 mm) (see Fig. 1). 
Fig. 1
When fixing ArGeTon ceramic bricks, an aluminium joint profile is used at the joints (see Fig. 3) and is held in place by the suspended ceramic brick itself. The joint profile not only finishes the joint but also protects it against wind and driving rain. It also prevents the ceramic bricks from rattling, so they do not shift.

Fig. 3 Joint profile Fig. 4 Omega damper
The Omega damper (see Fig. 4) prevents ArGeTon bricks from rattling. At building corners and at the side reveals of windows and doors it replaces the joint profile.
1. ArGeTon brick
2. Middle ArGeTon clip
3. T-profile (120 mm)
4. Mounting bracket (console)
5. Fixed at max. 70 cm centres
6. Thermal pad
7. Insulation
8. Top ArGeTon clip
9. Bottom ArGeTon clip
10. Fixing screw
11. Rivet or screw
Drawing 2. Vertical section of the T-substructure
1. ArGeTon brick
2. ArGeTon clip
3. T-profile (120 mm)
4. Mounting bracket (console), fixed at max. 70 cm centres
5. Thermal pad
6. Insulation
7. Joint profile
8. Omega damper
9. Fixing screw
10. Rivet or screw
Drawing 3. Horizontal section of the T-substructure
External and internal building corners
At external building corners, suspended ArGeTon ceramic bricks are joined using a corner profile or without a trim profile by mitre-cutting the bricks.
Corner profiles for external building corners:
1. Corner profile
2. Rivet or screw
3. Corner profile clip
4. Omega damper
5. ArGeTon brick
6. Joint profile
Drawing 4. External corner with trim profile
External corner without trim profile, using mitre-cut suspended ArGeTon ceramic bricks
Drawing 5. External corner without trim profile
At internal building corners, ArGeTon bricks are simply overlapped.
1. ArGeTon brick
2. ArGeTon clip
3. T-profile (120 mm)
4. Mounting bracket (console), fixed at max. 70 cm centres
5. Fixing screw
6. Thermal pad
7. Insulation
8. Omega damper
9. Joint profile
10. Rivet or screw
Drawing 6. Internal building corner