PRODUCTS

Installation

ArGeTon bricks can be fixed with one of two aluminium systems: a substructure of vertical or horizontal aluminium profiles.

ArGeTon installation instructions – download

Vertical aluminium T-substructure

This substructure consists of a mounting bracket (console) and a vertical “T” profile (120 mm) (see Fig. 1).

Fig. 1

  • The mounting bracket is fixed to the external wall through a thermal pad. The fixing spacing must equal the length of the ceramic bricks to be installed (see Drawing 1).
  • Next comes the insulation layer – mineral stone wool, whose thickness depends on the required thermal resistance.
  • A vertical T-profile is screwed to the mounting bracket, leaving a minimum 30 mm air gap from the stone wool. This ensures ventilation of the building walls.
  • Installation of the ceramic bricks starts at the bottom by screwing the bottom clips to the T-profile (see Fig. 2); the first row of ceramic bricks is placed on them.
  • The middle clips are fixed at a spacing (vertically) equal to the height of the ceramic brick. For example, if the specified brick height is 250 mm, the spacing between the clips (vertically) must be exactly 250 mm.
  • The following rows of middle clips are fixed at the same spacing.
  • To finish, the top row of bricks is fixed with the top clips (see Fig. 2).
  • Thanks to the design of the bricks and the shape of the clips, the clips are invisible once the facade is complete.

Fig. 2

When fixing ArGeTon ceramic bricks, an aluminium joint profile is used at the joints (see Fig. 3) and is held in place by the suspended ceramic brick itself. The joint profile not only finishes the joint but also protects it against wind and driving rain. It also prevents the ceramic bricks from rattling, so they do not shift.


Fig. 3 Joint profile Fig. 4 Omega damper

The Omega damper (see Fig. 4) prevents ArGeTon bricks from rattling. At building corners and at the side reveals of windows and doors it replaces the joint profile.

 

 

 

 

1. ArGeTon brick
2. Middle ArGeTon clip
3. T-profile (120 mm)
4. Mounting bracket (console)
5. Fixed at max. 70 cm centres
6. Thermal pad
7. Insulation
8. Top ArGeTon clip
9. Bottom ArGeTon clip
10. Fixing screw
11. Rivet or screw

 

 

 

 Drawing 2. Vertical section of the T-substructure

 

 

 

1. ArGeTon brick
2. ArGeTon clip
3. T-profile (120 mm)
4. Mounting bracket (console), fixed at max. 70 cm centres
5. Thermal pad
6. Insulation
7. Joint profile
8. Omega damper
9. Fixing screw
10. Rivet or screw

 

 

 

Drawing 3. Horizontal section of the T-substructure

External and internal building corners

At external building corners, suspended ArGeTon ceramic bricks are joined using a corner profile or without a trim profile by mitre-cutting the bricks.

Corner profiles for external building corners:

 


1. Corner profile
2. Rivet or screw
3. Corner profile clip
4. Omega damper
5. ArGeTon brick
6. Joint profile

 

 

 

 

 

Drawing 4. External corner with trim profile

 

External corner without trim profile, using mitre-cut suspended ArGeTon ceramic bricks

 

 

 

Drawing 5. External corner without trim profile

 

At internal building corners, ArGeTon bricks are simply overlapped.

 

 

 

 

1. ArGeTon brick
2. ArGeTon clip
3. T-profile (120 mm)
4. Mounting bracket (console), fixed at max. 70 cm centres
5. Fixing screw
6. Thermal pad
7. Insulation
8. Omega damper
9. Joint profile
10. Rivet or screw

 

 

 

 

Drawing 6. Internal building corner